SCHUKO socket outlet with residual current circuit-breaker enhanced contact protection, white glossy | |
Art No. | 47088982 |
EAN No. | 4011334280484 |
P.U. | 1 part |
Price * | on demand |
Price Group |
Design | according to DIN 49440 |
|
Nominal voltage | 250 V |
Rated current | 16 A |
Rated voltage | 250 V AC |
Measurement error current | 30 mA |
Surge current resistance | 250 A (8/20) µs |
Short-circuit resistance (with back-up fuse 20 AgL) | 3 kA |
Trigger time | ≤ 30 ms |
|
RAL colour | RAL 1013 - Oyster white |
Colour of design line | white |
Colour | white |
Colour | white |
Material | thermoplastic |
Surface appearance | glossy |
Insertion depth | 31,9 mm |
|
Connection terminals | according to IEC 60884-1 |
Connection terminals | according to VDE 0620-1 |
|
|
Tested | conform VDE 0664 (EN 61008) |
Protection index IP | IP20 |
IK protection code against mecanical impacts | 02 |
Enhanced contact protection | according to IEC 60884-1 |
Enhanced contact protection | according to VDE 0620-1 |
|
Secondary design line(s) | Berker S.1, Berker B.3, Berker B.7 |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
![]() |
Manual for 4708xx - SCHUKO socket outlet with residual current circuit-breaker (EN, 2010-12) |
PDF, 222 KB |
More (10) |
![]() |
Order Overview for Safety devices flush-mounted Safety devices flush-mounted |
PDF, 411 KB |
![]() |
Catalogue Chapter for Berker S.1 Berker S.1 |
PDF, 20,2 MB |
![]() |
Product Data Sheet for 47088982 SCHUKO socket outlet with residual current circuit-breaker enhanced contact protection, white glossy |
PDF, 523 KB |
Art No. | Description | P.U. | |
---|---|---|---|
![]() ![]() |
1913 | Extension claw for attaching | 50 prt. |