Motion detector with neutral conductor connection 1.1m Motion detectors
Product data sheet
Technical Properties
Download
  • Motion detector with neutral conductor connection 1.1m Motion detectors
    Art No. 2996
    EAN No. 4011334413738

    This product is not sold any longer.
    This page, however, remains available for information ourposes.
    Please contact your wholesaler in order to find appropriate follow-up products!

    Technical Characteristics
    Lockout time 2 s
    • with switch-off pre-warning (can be deactivated)
    • can only be used as individual unit
    • not suitable for the installation of stair light switches
    • with button for on/off/automatic
    Frequency 50/60 Hz
    Motor switching current at cosφ = 0.6 max. 1 A
    Fuse overheating protection (display using LEDs), short-circuit and overload proof (electronic fuse)
    Power consumption (standby) < 350 mW
    Conventional transformers max. 1000 VA
    Electronic transformers and dual-mode transformers max. 1000 W
    Relative humidity (without condensation) 0…90 % (without condensation)
    Detection field, semi-oval shaped ≈ 10 x 12 m
    Max. transmission range frontally 10 m
    Max. transmission range sideways 6 m
    Detection angle 180 °
    Detection angle, settable 180 °
    Colour polarwhite
    Material Plastic/metal
    Insertion depth 32 mm
    Nominal mounting height 1,1 m
    Response brightness, adjustable ≈ 5…1000 lx , daytime operation
    Fluorescent lamps max. 200 VA
    Compact fluorescent lamps max. 350 W
    Compact fluorescent lamps 350 W
    230V LED lamps max. 350 W
    LED with red status LED
    230 V incandescent lamps and halogen lamps max. 1000 W
    Screw terminals (max.) 2 x 1,5 ... 2,5 mm²
    Response value luminosity adjustable yes
    Response value sensitivity adjustable yes
    Response sensitivity, settable 10…100 %
    Delay time ≈ 3 mn
    • with 2 potentiometers for fine adjustment of the response brightness, sensitivity and delay time
    Operating temperature -5…45 °C
    Storage/transport temperature -20…60 °C (storage at > 45°C reduces the service life)
    Application, usage Motion detector
    Main design line Motion detectors
    Information text Only suitable for indoor areas!
  • Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    Manual for 2995, 2996 - Motion detector 1.1 m (2-/3-conductor) (EN-NL, 2017-10)
    PDF, 1,1 MB
    More (10)
    Motion detector with neutral conductor connection 1.1m Motion detectors Product Data Sheet for 2996
    Motion detector with neutral conductor connection 1.1m Motion detectors
    PDF, 634 KB
All data is subject to errors and technical modifications.